SAM® MicroSound NCR Units

Standard Series:
APPLICATIONS
SAM MICROSOUND NCR | SAM MICROSOUND GS | SAM MICROSOUND 3S NCR | SAM MICROSOUND 3S GS | SAM MICROSOUND GS LI | SAM MICROSOUND ECM | SAM REPLACEMENT FILTERS and PARTS

Options:
SAMLINK CONTROL SYSTEMS  |  CONSTANT VELOCITY  |  MAGNEHELIC GAGES
CEILING COLLARS & SHEET ROCK ADAPTERS  |  DUCT COLLAR ADAPTER
FINAL FILTERS  |  GRILLES & KNIFE EDGE  |  PILOT LIGHT, POWER CORD & PREFILTER
ROOMSIDE SPEED CONTROL, AEROSOL PORT & STATIC CONTROL

Return to SAM OVERVIEW Page


421_SAM_MS_Models1SAM
® MicroSound

SAM MicroSound Fan Filter Units include a 99.99% efficient HEPA filter, 30% ASHRAE pleated type prefilter, seismic clip suspension points, safety switch which disables the unit while servicing, and solid state variable speed control with RFI suppression, allowing the airflow to be fine tuned.

Housings are fabricated from steel with a white powdercoat finish and include seismic clip suspension points.

The energy efficient N310 motor blower is a low watt backward curved impeller,  single phase, permanent split capacitor type motor blower assembly with thermal overload protection. Units are available in 115 Volt (60 Hz), 208-230 Volt (50/60 Hz) and 277 Volt (60 Hz).

Final filters are protected with a white epoxy diamond pattern grille and are tested according to accepted procedures as described by the Institute of Environmental Sciences (IEST) and/or ISO standards. The standard HEPA filter is 99.99% eff. and an ULPA grade 99.9995% eff. filter is available as an option.

Other popular options include an 8’ power cord (115 Volt only), 99.9995% eff. ULPA grade final filter, UL 900 filters and duct collar adapters. Refer to the back of this section for more options and accessories.

For horizontal flow applications consult with one of our cleanroom experts in your area, or call the factory for more information.

SAM is a registered trademark owned by Clean Rooms International


NCR Style Filter Data: The HEPA Filters are designed for 90 FPM average face velocity @ initial 0.47 w.g. and have a rated efficiency of 99.99% @ 0.3 micron or larger. An anodized aluminum frame holds the 53mm media which is protected by a diamond pattern white epoxy coated steel grille.

Final filters can be replaced by removing unit from ceiling, placing on a bench, removing and replacing the filter and re-installing unit in ceiling.

Low Profile: All SAM MicroSound NCR Style Models are
12-5/8” high.

Standard Ceiling Size: All 2’ x 4’ models are designed to fit a nominal 2’ x 4’ ceiling grid with a 22.5” x 46.5” standard opening.

Air Flow: Airflow ranges from 400 to 750 CFM for a 2 x 4 unit and 250 to 400 CFM for a 2 x 2 unit. At 90 FPM, CFM is nominal 632 on a 2 x 4 and 300 on a 2 x 2 unit respectively. Airflow for units running at 50 Hz will be about 20% less.

Sound Level: At average face velocity of 90 FPM measured 30” from face of filter, sound level is approximately 54 dba with less than 45 dba ambient sound level. Field conditions, voltage and method of testing could produce different results.

Motor Data
Motor Voltage Hz Watts Running Amps Start-Up Amps
N310 115 60 185 1.6 4.1
N310 208-230 50/60 165 0.8-0.7(1) 1.5(2)
N310 277 60 165 0.6 1.5
  1. Running amps will be less on 50Hz
  2. Line voltage can affect actual start-up amperage
Replacement Filters
Mfg. Code Description
302070 2×2 NCR Style HEPA Filter, 99.99% eff. @ 0.3 micron
302071 2×2 NCR Style ULPA Filter, 99.9995% eff. @ 0.12 micron
302013 2×3 NCR Style HEPA Filter, 99.99% eff. @0.3 micron
302015 2×3 NCR Style ULPA Filter, 99.9995% eff. @ 0.12 micron
302090 2×4 NCR Style HEPA Filter, 99.99% eff. @ 0.3 micron
302100 2×4 NCR Style ULPA Filter, 99.9995% eff. @ 0.12 micron
302190 Prefilter 20″x20″x1″, 30% ASHRAE efficient, pleated type
Base Model
(Ordering Information)
Mfg. Code Model or Description Style Size Voltage Motor Variable Speed Control HEPA Filter Weight
12100* SAM22 MS NCR NCR 2 x 2 115 N310 703084 302070 53 lbs. (24.0 kg.)
12101 SAM22 MS NCR NCR 2 x 2 208-230 N310 703912 302070 53 lbs. (24.0 kg.)
12102* SAM22 MS NCR NCR 2 x 2 277 N310 703915 302070 53 lbs. (24.0 kg.)
12150* SAM23 MS NCR NCR 2 x 3 115 N310 703084 302013 57 lbs. (25.9 kg.)
12151 SAM23 MS NCR NCR 2 x 3 208-230 N310 703912 302013 57 lbs. (25.9 kg.)
12152* SAM23 MS NCR NCR 2 x 3 277 N310 703915 302013 57 lbs. (25.9 kg.)
12261* SAM24 MS NCR NCR 2 x 4 115 N310 703084 302090 60 lbs. (27.2 kg.)
12262 SAM24 MS NCR NCR 2 x 4 208-230 N310 703912 302090 60 lbs. (27.2 kg.)
12263* SAM24 MS NCR NCR 2 x 4 277 N310 703915 302090 60 lbs. (27.2 kg.)

* UL Listed
Prefilter and Safety Switch are Standard on all Models

Popular Options: (Please choose from the following part numbers when ordering options)
Final Filters: Air Conditioning Mixing Box:
302071  2 x 2 NCR ULPA Filter 99.9995% eff. 19958  Slanted Top with 10” Duct Collar
302015  2 x 3 NCR ULPA Filter 99.9995% eff. 19959  Slanted Top with 12” Duct Collar
302100  2 x 4 NCR ULPA Filter 99.9995% eff.  19947  Square with (2) 10” Duct Collars
308001  2 x 2 NCR HEPA UL 900 19948  Square with (2) 12” Duct Collars
308002  2 x 4 NCR HEPA UL 900 Pilot Light:
308005  2 x 4 NCR ULPA UL 900 19700  NCR Style Red Pilot Light- (w/36″ lead for grid or ceiling mount (Light Indicates Power to Motor)
308007  2 x 2 NCR ULPA UL 900 19701  NCR Style Red Pilot Light w/Pressure Switch- (w/36″ lead for grid or ceiling mount (Light Indicates Power to Motor and Air Flow)
302072  2 x 2 NCR HEPA with Centerboard and Test Port Radial Diffuser Grille:
302094  2 x 4 NCR HEPA with Centerboard and Test Port 19300  2 x 2 Radial Diffuser Grille
Prefilters:  19301  2 x 4 Radial Diffuser Grille
302197  Extended Life Prefilter 20″ x 20″ x 2″  Miscellaneous:
Duct Collar Adapters: 703902  8’ Power Cord 110-120V Only
19950  10” Duct Collar Adapter  603322  Gasket on Downstream Edge of Unit
19951  12” Duct Collar Adapter  Magnehelic Gage: Refer to the Back of this Section
19952  Side Load with 10” Duct Collar
19953  Side Load with 12” Duct Collar
19955  10” Top Load Duct Collar Adapter
19956  12” Top Load Duct Collar Adapter

NOTE: Duct collar adapters #19950 & #19951 may be used without negating the UL listing. All other duct collars, air conditioning boxes, pilot lights, and adding other electrical components negates UL listing.