SAM® Microsound ECM Units

Standard Series: APPLICATIONS SAM MICROSOUND NCR | SAM MICROSOUND GS | SAM MICROSOUND 3S NCR | SAM MICROSOUND 3S GS | SAM MICROSOUND GS LI | SAM MICROSOUND ECM | SAM REPLACEMENT FILTERS and PARTS

Options: SAMLINK CONTROL SYSTEMS  |  CONSTANT VELOCITY  |  MAGNEHELIC GAGES CEILING COLLARS & SHEET ROCK ADAPTERS  |  DUCT COLLAR ADAPTER FINAL FILTERS  |  GRILLES & KNIFE EDGE  |  PILOT LIGHT, POWER CORD & PREFILTER   |  ROOMSIDE SPEED CONTROL, AEROSOL PORT & STATIC CONTROL

Return to SAM OVERVIEW Page

Automatically Adjusts to Maintain Constant AirflowSAM_ECM_Illust2b_1

SAM MicroSound ECM fan filter units key features include…

• A local potentiometer to set desired airflow.
• Digital speed display.
• An electronically commutated motor that is programmed to increase the speed as the load increases to maintain a constant airflow.
• Low power consumption.
• Low sound levels.

UL_Symb

SAM MicroSound ECM GS units feature a roomside removable filter element with a gel channel on the upstream side of the final filter which provides a leak-free seal between the filter and the filter housing.

SAM MicroSound ECM NCR units feature a low profile unit with an upstream gasket for a leakfree seal between the final filter and the SAM plenum.

Housings are fabricated from steel with a white powdercoat finish.

The ECM motor blower is a 1/3 HP, motor with a forward curved blower. Units are available in 115V (60 Hz), 208-230V (50/60Hz) and 277V (60 Hz).

SAM MicroSound Fan Filter Units include a 99.99% efficient HEPA filter, 30% ASHRAE pleated type prefilter, seismic clip suspension points.

Final filters are protected with a white epoxy diamond pattern grille and are tested according to accepted procedures as described by the Institute of Environmental Sciences (IEST) and/or ISO standards. The standard HEPA filter is 99.99% eff. and an ULPA grade 99.9995% eff. filter is available as an option.

A polystyrene eggcrate grille in an anodized aluminum frame is hinged to open, permitting removal of the filter without removing the unit from the ceiling (GS models only). Optional perforated stainless steel or aluminum grilles are available.

Some of the many available options include: roomside motor access and challenge ports, duct collars, ULPA filtration and stainless steel construction.

Many control options are available, including MODBUS RTU protocol networking, infrared remote control, roomside digital display, or a complete SAMlink Control System.

For other control options or further information please consult with your Clean Rooms International representative or contact the factory.


GS-Style Filter Data: The HEPA Filter is designed for 90 FPM average face velocity @ SAM_MS_ECM_GS_Dtls2b_1initial 0.47 w.g. and has a rated efficiency of 99.99% @ 0.3 micron or larger. An anodized aluminum frame holds the 53mm media which is protected by a diamond pattern white epoxy coated steel grille. Final filters are replaceable from roomside.

NCR-Style Filter Data: The HEPA Filters are designed for 90 FPM average face velocity @ initial 0.47 w.g. and have a rated efficiency of 99.99% @ 0.3 micron or larger. An anodized aluminum frame holds the 53mm media which is protected by a diamond pattern white epoxy coated steel grille.

Final filters can be replaced by removing unit from ceiling, placing on a bench, removing and replacing the filter and re-installing unit in ceiling. SAM_MS_ECM_NCR_Dtls2b_1 Access Port (GS Style Only): This port is located in the center of the filter element face and is used for introducing an upstream challenge or measuring static pressure.

Air Flow: Designed for 90 FPM +/- 20%. On 2×4 units at 90 FPM, the CFM is 630 for the NCR style and 520 for the GS style.

Sound Level: At 90 FPM with a clean unloaded HEPA filter and zero e.s.p. the sound level is 50-53 dBa. See table below.

SAM_ECM_ControlBxDtl_2c_1

Base Model
(Ordering Information)
Mfg. Code Model or Description Style Size Voltage Motor HEPA Filter Weight
12327 SAM22 MS ECM NCR NCR 2×2 115 ECM 302070 66 lbs. (29.9 kg.)
12328 SAM22 MS ECM NCR NCR 2×2 208-230 ECM 302070 66 lbs. (29.9 kg.)
12329 SAM22 MS ECM NCR NCR 2×2 277 ECM 302070 66 lbs. (29.9 kg.)
12333 SAM24 MS ECM NCR NCR 2×4 115 ECM 302090 77 lbs. (34.9 kg.)
12334 SAM24 MS ECM NCR NCR 2×4 208-230 ECM 302090 77 lbs. (34.9 kg.)
12335 SAM24 MS ECM NCR NCR 2×4 277 ECM 302090 77 lbs. (34.9 kg.)
12330 SAM22 MS ECM GS GS 2×2 115 ECM 302201 81 lbs. (36.7 kg.)
12331 SAM22 MS ECM GS GS 2×2 208-230 ECM 302201 81 lbs. (36.7 kg.)
12332 SAM22 MS ECM GS GS 2×2 277 ECM 302201 81 lbs. (36.7 kg.)
12336 SAM24 MS ECM GS GS 2×4 115 ECM 302200 101 lbs. (45.8 kg.)
12337 SAM24 MS ECM GS GS 2×4 208-230 ECM 302200 101 lbs. (45.8 kg.)
12338 SAM24 MS ECM GS GS 2×4 277 ECM 302200 101 lbs. (45.8 kg.)
Performance Data* (2 x 4 units**)
Style Motor Voltage Hz Watts @ 90FPM CFM @ 90FPM Running Amps @90FPM
NCR ECM 115 60 135 630 1.82
NCR ECM 208-230 50/60 135 630 1.10
NCR ECM 277 60 135 630 0.79
GS ECM 115 60 96 520 1.34
GS ECM 208-230 50/60 96 520 0.78
GS ECM 277 60 96 520 0.58

* Based on 60Hz, without a prefilter, 0.0″ ESP
** Consult factory for 2×2 units Performance testing based on Shortage multi-point velgrid with 2″ standoffs

Replacement Filters
Mfg. Code Description
302201 2×2 GS Style HEPA Filter, 99.99% eff. @ 0.3 micron
302204 2×2 GS Style ULPA Filter, 99.9995% eff. @ 0.12 micron
302200 2×4 GS Style HEPA Filter, 99.99% eff. @ 0.3 micron
302203 2×4 GS Style ULPA Filter, 99.9995% eff. @ 0.12 micron
302070 2×2 NCR Style HEPA Filter, 99.99% eff. @ 0.3 micron
302071 2×2 NCR Style ULPA Filter, 99.9995% eff. @ 0.12 micron
302090 2×4 NCR Style HEPA Filter, 99.99% eff. @ 0.3 micron
302100 2×4 NCR Style ULPA Filter, 99.9995% eff. @ 0.12 micron
302190 Prefilter 20″x20″x1″, 30% ASHRAE efficient, pleated type
Popular Options: (Please choose from the following part numbers when ordering options)
Final Filters: Air Conditioning Mixing Box:
302204  2 x 2 GS ULPA Filter 99.9995% eff. 19958  Slanted Top with 10” Duct Collar
302203  2 x 4 GS ULPA Filter 99.9995% eff. 19959  Slanted Top with 12” Duct Collar
302071  2 x 2 NCR ULPA Filter 99.9995% eff. 19947  Square with (2) 10” Duct Collars
302100  2 x 4 NCR ULPA Filter 99.9995% eff. 19948  Square with (2) 12” Duct Collars
Prefilters: Control Options:
302197 Extended Life Prefilter 20″ x 20″ x 2″ Roomside Speed Display/Control
Duct Collar Adapters: MODBUS RTU Network
*19950  10” Duct Collar Adapter SAMlink System w/PLC
*19951  12” Duct Collar Adapter Infrared Remote
*19952  Side Load with 10” Duct Collar Pilot Light:
*19953  Side Load with 12” Duct Collar 19700  NCR Style Red Pilot Light – (w/36″ lead for grid or ceiling mount) Light Indicates Power to Motor)
Grilles 1/8” Round Perforated: (40% open area) 19701  NCR Style Red Pilot Light w/Pressure Switch – (w/36″ lead for grid or ceiling mount) Light Indicates Power to Motor and Air Flow)
19506  2 x 2 CRF Anodized Alum. Grille and Frame 19702  GS/CRF Style Red Pilot Light – factory mounted in grille frame (Light Indicates Power to Motor)
19507  2 x 4 CRF Anodized Alum. Grille and Frame 19703  GS/CRF Style Red Pilot Light w/Pressure Switch – factory mounted in grille frame (Light Indicates Air Flow)
19508  2 x 2 CRF Round Perf w/1/8” Holes, White Powdercoated Grille and Frame Miscellaneous:  
19509  2 x 4 CRF Round Perf w/1/8” Holes, White Powdercoated Grille and Frame  703902  8’ Power Cord 110-120V Only
19511  2 x 4 CRF S.S. Rnd. Perf Grille w/Anodized Alum. Frame  603322  Gasket on Downstream Edge of Unit
19512  2 x 2 CRF S.S. Rnd. Perf Grille w/Anodized Alum. Frame  Magnehelic Gage: Refer to the Back of this Section
19525  2 x 2 CRF S.S. Perf Grille w/S.S Frame  Static Control: Refer to the Back of this Section
19514  2 x 4 CRF S.S. Perf Grille w/S.S Frame

*When using on house HVAC systems, Please consult factory.

NOTE: Duct collar adapters #19950 & #19951 may be used without negating the UL listing. All other duct collars, air conditioning boxes, pilot lights, and adding other electrical components negates UL listing.