SAM® MicroSound 3S NCR Style

Standard Series:
APPLICATIONS
SAM MICROSOUND NCR | SAM MICROSOUND GS | SAM MICROSOUND 3S NCR | SAM MICROSOUND 3S GS | SAM MICROSOUND GS LI | SAM MICROSOUND ECM | SAM REPLACEMENT FILTERS and PARTS

Options:
SAMLINK CONTROL SYSTEMS | CONSTANT VELOCITY | MAGNEHELIC GAGES
CEILING COLLARS & SHEET ROCK ADAPTERS | DUCT COLLAR ADAPTER
FINAL FILTERS | GRILLES & KNIFE EDGE | PILOT LIGHT, POWER CORD & PREFILTER
ROOMSIDE SPEED CONTROL, AEROSOL PORT & STATIC CONTROL

Return to SAM OVERVIEW Page


425_SAM_MS3S_NCR_Models11/5 HP
3-Speed Fan Powered Filter Module
Low Sound, Economical

SAM MS 3-S Fan Filter Units provide quiet performance and economy while delivering 90 FPM airflow velocities, perfect for most cleanroom applications. Base design includes a 99.99% efficient HEPA filter, a prefilter and a 3-speed switch with an off position which disables the unit while servicing.

Housings are fabricated from steel with a white powdercoat finish and include seismic clip suspension points.

The 1/5 HP motor blower is a forward curved direct drive motor/blower assembly with isolation mounts. Units are available in 115 Volt (60 Hz) and 277 Volt (60 Hz).

Final filters are protected with a white epoxy diamond pattern grille and are tested according to accepted procedures as described by the Institute of Environmental Sciences (IEST) and/or ISO standards. The standard HEPA filter is 99.99% eff. and an ULPA grade 99.9995% eff. filter is available as an option.

 Optional perforated stainless steel or aluminum grilles are available.

Other popular options include an 8’ power cord (115 Volt only). Refer to the back of this section for more options and accessories.

 

SAM is a registered trademark owned by Clean Rooms International


NCR Style Filter Data:

The HEPA Filters are designed for 90 FPM average face velocity @ initial 0.47 w.g. and have a rated efficiency of 99.99% @ 0.3 micron or larger. An anodized aluminum frame holds the 53mm media which is protected by a diamond pattern white epoxy coated steel grille.

Final filters can be replaced by removing unit from ceiling, placing on a bench, removing and replacing the filter and re-installing unit in ceiling.

Low Profile: All SAM MicroSound NCR Style Models are 12-5/8″ high.

 Air Flow: Airflow ranges from 500 to 750 CFM for a 2 x 4 unit and 250 to 400 CFM for a 2 x 2 unit. At 90 FPM, CFM is nominal 632 on a 2 x 4 and 300 on a 2 x 2 unit respectively.

General Information:

Standard Ceiling Size: All 2’ x 4’ models are designed to fit a nominal 2’ x 4’ ceiling grid with a 22.5″ x 46.5″ standard opening.

Sound Level: At average face velocity of 90 FPM measured 30″ from face of filter, sound level is approximately 50-52 dba with less than 45 dba ambient sound level. Field conditions, voltage and method of testing could produce different results.

Popular Options: Scroll down below the tables for a list of popular options.

 

Motor Data
Motor Voltage Hz Amps Start-Up Amps (1, 2)
Low Med High Low Med High
1/5 HP 115 60 1.45 1.95 2.85 1.70 2.60 5.0
1/5 HP 277 60 0.52 0.71 1.1 0.60 0.85 1.5
  1. Line voltage can affect actual start-up amperage
  2. Use standard NEC tables for sizing circuits
Replacement Filters
Mfg. Code Description
302070 2×2 NCR Style HEPA Filter, 99.99% eff. @ 0.3 micron
302071 2×2 NCR Style ULPA Filter, 99.9995% eff. @ 0.12 micron
302013 2×3 NCR Style HEPA Filter, 99.99% eff. @0.3 micron
302015 2×3 NCR Style ULPA Filter, 99.9995% eff. @ 0.12 micron
302090 2×4 NCR Style HEPA Filter, 99.99% eff. @ 0.3 micron
302100 2×4 NCR Style ULPA Filter, 99.9995% eff. @ 0.12 micron
302190 Prefilter 20″x20″x1″, 30% ASHRAE efficient, pleated type
Base Model
(Ordering Information)
Mfg. Code Model or Description Style Size Voltage Motor HEPA Filter Weight
12339 SAM22 MS 3S NCR* NCR 2 x 2 115 1/5 HP 302070 58 lbs. (26.3 kg.)
12340 SAM22 MS 3S NCR* NCR 2 x 2 277 1/5 HP 302070 58 lbs. (26.3 kg.)
12343 SAM23 MS 3S NCR* NCR 2 x 3 115 1/5 HP 302013 62 lbs. (28.1 kg.)
12344 SAM23 MS 3S NCR* NCR 2 x 3 277 1/5 HP 302013 62 lbs. (28.1 kg.)
12347 SAM24 MS 3S NCR* NCR 2 x 4 115 1/5 HP 302090 65 lbs. (29.5 kg.)
12348 SAM24 MS 3S NCR* NCR 2 x 4 277 1/5 HP 302090 65 lbs. (29.5 kg.)

* UL Listed
3 Speed Switch Standard on all Models

Popular Options: (Consult with factory for other possible options)
Speed Control: Prefilters:
SAMLink Remote Speed Control System 19700  NCR Style Red Pilot Light- (w/36″ lead for grid or ceiling mount) Light Indicates Power to Motor
Solid State Variable Speed Controller 19701  NCR Style Red Pilot Light w/Pressure Switch- (w/36″ lead for grid or ceiling mount) Light Indicates Power to Motor and Air Flow
Final Filters: Air Conditioning Mixing Box:
302071  2 x 2 NCR ULPA Filter 99.9995% eff. 19958  Slanted Top with 10” Duct Collar
302015  2 x 3 NCR ULPA Filter 99.9995% eff. 19959  Slanted Top with 12” Duct Collar
302100  2 x 4 NCR ULPA Filter 99.9995% eff. 19947  Square with (2) 10” Duct Collars
308001  2 x 2 NCR HEPA 19948  Square with (2) 12” Duct Collars
308002  2 x 4 NCR HEPA Radial Diffuser Grille:
308005  2 x 4 NCR ULPA 19300  2 x 2 Radial Diffuser Grille
308007  2 x 2 NCR ULPA 19301  2 x 4 Radial Diffuser Grille
302072  2 x 2 NCR HEPA with Centerboard and Test Port Miscellaneous:
302094  2 x 4 NCR HEPA with Centerboard and Test Port 703902  8’ Power Cord 110-120V Only
Prefilters: 603322  Gasket on Downstream Edge of Unit
302197  Extended Life Prefilter 20″ x 20″ x 2″ Magnehelic Gage: Refer to the Back of this Section
Duct Collar Adapters: Static Control: Refer to the Back of this Section
19950  10” Duct Collar Adapter
19951  12” Duct Collar Adapter
19952  Side Load with 10” Duct Collar
19953  Side Load with 12” Duct Collar
19955  10” Top Load Duct Collar Adapter
19956  12” Top Load Duct Collar Adapter

NOTE: Duct collar adapters #19950 & #19951 may be used without negating the UL listing. All other duct collars, air conditioning boxes, pilot lights, and adding other electrical components negates UL listing.