1/5 HP
3-Speed Fan Powered Filter Module
Low Sound, Economical
SAM MS 3-S Fan Filter Units provide quiet performance and economy while delivering 90 FPM airflow velocities, perfect for most cleanroom applications. Base design includes a 99.99% efficient HEPA filter, a prefilter and a 3-speed switch with an off position which disables the unit while servicing.
Housings are fabricated from steel with a white powdercoat finish and include seismic clip suspension points.
The 1/5 HP motor blower is a forward curved direct drive motor/blower assembly with isolation mounts. Units are available in 115 Volt (60 Hz) and 277 Volt (60 Hz).
Final filters are protected with a white epoxy diamond pattern grille and are tested according to accepted procedures as described by the Institute of Environmental Sciences (IEST) and/or ISO standards. The standard HEPA filter is 99.99% eff. and an ULPA grade 99.9995% eff. filter is available as an option.
Optional perforated stainless steel or aluminum grilles are available.
Other popular options include an 8’ power cord (115 Volt only). Refer to the back of this section for more options and accessories.
SAM is a registered trademark owned by Clean Rooms International Inc.
The HEPA Filters are designed for 90 FPM average face velocity @ initial 0.47 w.g. and have a rated efficiency of 99.99% @ 0.3 micron or larger. An anodized aluminum frame holds the 53mm media which is protected by a diamond pattern white epoxy coated steel grille.
Final filters can be replaced by removing unit from ceiling, placing on a bench, removing and replacing the filter and re-installing unit in ceiling.
Low Profile: All SAM MicroSound NCR Style Models are 12-5/8″ high.
Air Flow: Airflow ranges from 500 to 750 CFM for a 2 x 4 unit and 250 to 400 CFM for a 2 x 2 unit. At 90 FPM, CFM is nominal 632 on a 2 x 4 and 300 on a 2 x 2 unit respectively.
General Information:
Standard Ceiling Size: All 2’ x 4’ models are designed to fit a nominal 2’ x 4’ ceiling grid with a 22.5″ x 46.5″ standard opening.
Sound Level: At average face velocity of 90 FPM measured 30″ from face of filter, sound level is approximately 50-52 dba with less than 45 dba ambient sound level. Field conditions, voltage and method of testing could produce different results.
Popular Options: Scroll down below the tables for a list of popular options.
Motor Data | ||||||||
---|---|---|---|---|---|---|---|---|
Motor | Voltage | Hz | Amps | Start-Up Amps (1, 2) | ||||
Low | Med | High | Low | Med | High | |||
1/5 HP | 115 | 60 | 1.45 | 1.95 | 2.85 | 1.70 | 2.60 | 5.0 |
1/5 HP | 277 | 60 | 0.52 | 0.71 | 1.1 | 0.60 | 0.85 | 1.5 |
Replacement Filters | |
---|---|
Mfg. Code | Description |
302070 | 2×2 NCR Style HEPA Filter, 99.99% eff. @ 0.3 micron |
302071 | 2×2 NCR Style ULPA Filter, 99.9995% eff. @ 0.12 micron |
302013 | 2×3 NCR Style HEPA Filter, 99.99% eff. @0.3 micron |
302015 | 2×3 NCR Style ULPA Filter, 99.9995% eff. @ 0.12 micron |
302090 | 2×4 NCR Style HEPA Filter, 99.99% eff. @ 0.3 micron |
302100 | 2×4 NCR Style ULPA Filter, 99.9995% eff. @ 0.12 micron |
302190 | Prefilter 20″x20″x1″, 30% ASHRAE efficient, pleated type |
Base Model (Ordering Information) |
|||||||
---|---|---|---|---|---|---|---|
Mfg. Code | Model or Description | Style | Size | Voltage | Motor | HEPA Filter | Weight |
12339 | SAM22 MS 3S NCR* | NCR | 2 x 2 | 115 | 1/5 HP | 302070 | 58 lbs. (26.3 kg.) |
12340 | SAM22 MS 3S NCR* | NCR | 2 x 2 | 277 | 1/5 HP | 302070 | 58 lbs. (26.3 kg.) |
12343 | SAM23 MS 3S NCR* | NCR | 2 x 3 | 115 | 1/5 HP | 302013 | 62 lbs. (28.1 kg.) |
12344 | SAM23 MS 3S NCR* | NCR | 2 x 3 | 277 | 1/5 HP | 302013 | 62 lbs. (28.1 kg.) |
12347 | SAM24 MS 3S NCR* | NCR | 2 x 4 | 115 | 1/5 HP | 302090 | 65 lbs. (29.5 kg.) |
12348 | SAM24 MS 3S NCR* | NCR | 2 x 4 | 277 | 1/5 HP | 302090 | 65 lbs. (29.5 kg.) |
* UL Listed
3 Speed Switch Standard on all Models
Popular Options: (Consult with factory for other possible options) | |
---|---|
Speed Control: | Prefilters: |
SAMLink Remote Speed Control System | 19700 NCR Style Red Pilot Light- (w/36″ lead for grid or ceiling mount) Light Indicates Power to Motor |
Solid State Variable Speed Controller | 19701 NCR Style Red Pilot Light w/Pressure Switch- (w/36″ lead for grid or ceiling mount) Light Indicates Power to Motor and Air Flow |
Final Filters: | Air Conditioning Mixing Box: |
302071 2 x 2 NCR ULPA Filter 99.9995% eff. | 19958 Slanted Top with 10” Duct Collar |
302015 2 x 3 NCR ULPA Filter 99.9995% eff. | 19959 Slanted Top with 12” Duct Collar |
302100 2 x 4 NCR ULPA Filter 99.9995% eff. | 19947 Square with (2) 10” Duct Collars |
308001 2 x 2 NCR HEPA | 19948 Square with (2) 12” Duct Collars |
308002 2 x 4 NCR HEPA | Radial Diffuser Grille: |
308005 2 x 4 NCR ULPA | 19300 2 x 2 Radial Diffuser Grille |
308007 2 x 2 NCR ULPA | 19301 2 x 4 Radial Diffuser Grille |
302072 2 x 2 NCR HEPA with Centerboard and Test Port | Miscellaneous: |
302094 2 x 4 NCR HEPA with Centerboard and Test Port | 703902 8’ Power Cord 110-120V Only |
Prefilters: | 603322 Gasket on Downstream Edge of Unit |
302197 Extended Life Prefilter 20″ x 20″ x 2″ | Magnehelic Gage: Refer to the Back of this Section |
Duct Collar Adapters: | Static Control: Refer to the Back of this Section |
19950 10” Duct Collar Adapter | |
19951 12” Duct Collar Adapter | |
19952 Side Load with 10” Duct Collar | |
19953 Side Load with 12” Duct Collar | |
19955 10” Top Load Duct Collar Adapter | |
19956 12” Top Load Duct Collar Adapter |
NOTE: Duct collar adapters #19950 & #19951 may be used without negating the UL listing. All other duct collars, air conditioning boxes, pilot lights, and adding other electrical components negates UL listing.